Material Name: YTTRIUM NITRATE, HEXAHYDRATE SDS ID: ohs25200 Issue Date: 2016-06-23 Revision: 2.07 |
YTTRIUM NITRATE, HEXAHYDRATE
ChemADVISOR, Inc.Stone Quarry Crossing 811 Camp Horne Road, Suite 220 Pittsburgh, PA 15237E-mail: info@chemadvisor.com MSDS is for reference use only; please contact manufacturer for emergency response information, routine product inquiries and orders. |
inorganic, salt
NITRIC ACID, YTTRIUM(3+) SALT; YTTRIUM(III) NITRATE (1:3); NITRIC ACID, YTTRIUM(III) SALT; YTTRIUM(III) NITRATE HEXAHYDRATE (1:3:6); Y-4; NITRIC ACID, YTTRIUM(3+) SALT, HEXAHYDRATE; YTTRIUM TRINITRATE HEXAHYDRATE
Emergency Overview
Color: colorless to pink
Change in color: deliquescent
Physical Form: crystals
Odor: odorless
Health Hazards: respiratory tract irritation, eye irritation
Short Term: irritation, lung damage
Long Term: no information is available
Short Term: no information is available
Long Term: no information is available
Short Term: irritation
Long Term: no information is available
Short Term: no information is available
Long Term: liver damage
CAS EC No Registration No | Component Name Synonyms | 1272/2008 (CLP) | Percent |
13494-98-9 -- -- | YTTRIUM NITRATE, HEXAHYDRATE | -- | 100 |
This product may be regulated, have exposure limits or other information identified as the following: Yttrium compounds.
If adverse effects occur, remove to uncontaminated area. Give artificial respiration if not breathing. Get immediate medical attention.
Wash skin with soap and water for at least 15 minutes while removing contaminated clothing and shoes. Get medical attention, if needed. Thoroughly clean and dry contaminated clothing and shoes before reuse.
Flush eyes with plenty of water for at least 15 minutes. Then get immediate medical attention.
Contact local poison control center or physician immediately. Never make an unconscious person vomit or drink fluids. When vomiting occurs, keep head lower than hips to help prevent aspiration. If person is unconscious, turn head to side. Get medical attention.
See Section 9 for Flammability Properties
Negligible fire hazard.
water Do not use dry chemicals, carbon dioxide or halogenated extinguishing agents. Large fires: Flood with water. Apply water from a protected location or from a safe distance.
Move container from fire area if it can be done without risk. Cool containers with water spray until well after the fire is out. Stay away from the ends of tanks. For fires in cargo or storage area: Cool containers with water from unmanned hose holder or monitor nozzles until well after fire is out. If this is impossible then take the following precautions: Keep unnecessary people away, isolate hazard area and deny entry. Let the fire burn. Flood with fine water spray. Do not scatter spilled material with high-pressure water streams. Cool containers with water spray until well after the fire is out. Apply water from a protected location or from a safe distance. Avoid inhalation of material or combustion by-products. Stay upwind and keep out of low areas. Explosive. Evacuation radius: 800 meters (1/2 mile).
Avoid contact with combustible materials. Do not touch spilled material. Small dry spills: Move containers away from spill to a safe area. Small liquid spills: Absorb with sand or other non-combustible material. Collect spilled material in appropriate container for disposal. Large spills: Dike for later disposal. Keep unnecessary people away, isolate hazard area and deny entry.
Store and handle in accordance with all current regulations and standards.
Component Exposure Limits
YTTRIUM NITRATE, HEXAHYDRATE | 13494-98-9 |
ACGIH: | 1 mg/m3 TWA as Y (related to Yttrium compounds) |
NIOSH: | 1 mg/m3 TWA as Y (related to Yttrium compounds) |
500 mg/m3 IDLH as Y (related to Yttrium compounds) |
Biological limit value
Provide local exhaust or process enclosure ventilation system. Ensure compliance with applicable exposure limits.
Eyes/Face Wear splash resistant safety goggles with a faceshield. Provide an emergency eye wash fountain and quick drench shower in the immediate work area.
Wear appropriate chemical resistant clothing.
Wear appropriate chemical resistant gloves.
The following respirators and maximum use concentrations are drawn from NIOSH and/or OSHA. Measurement Element: Yttrium (Y) 5 mg/m3 Any quarter-mask respirator. 10 mg/m3 Any particulate respirator equipped with an N95, R95, or P95 filter (including N95, R95, and P95 filtering facepieces) except quarter-mask respirators. The following filters may also be used: N99, R99, P99, N100, R100 or P100. Any supplied-air respirator. 25 mg/m3 Any supplied-air respirator operated in a continuous-flow mode. Any powered, air-purifying respirator with a high-efficiency particulate filter. 50 mg/m3 Any air-purifying, full-facepiece respirator equipped with an N100, R100, or P100 filter. Any supplied-air respirator with a tight-fitting facepiece that is operated in a continuous-flow mode. Any powered, air-purifying respirator with a tight-fitting facepiece and a high-efficiency particulate filter. Any self-contained breathing apparatus with a full facepiece. Any supplied-air respirator with a full facepiece. 500 mg/m3 Any supplied-air respirator operated in a pressure-demand or other positive-pressure mode. Emergency or planned entry into unknown concentrations or IDLH conditions - Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode. Any supplied-air respirator with a full facepiece that is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained breathing apparatus operated in pressure-demand or other positive-pressure mode. Escape - Any air-purifying, full-facepiece respirator equipped with an N100, R100, or P100 filter. Any appropriate escape-type, self-contained breathing apparatus.
Appearance | Not available | Physical State | Solid |
Odor | odorless | Color | colorless to pink |
Odor Threshold | Not available | pH | (acidic in solution) |
Melting Point | 100 °C (loses water) | Boiling Point | (decomposes) |
Freezing point | Not available | Evaporation Rate | Not available |
Boiling Point Range | Not available | Flammability (solid, gas) | Not available |
Autoignition | Not available | Flash Point | Not available |
Lower Explosive Limit | (decomposes) | Decomposition | Not available |
Upper Explosive Limit | (decomposes) | Vapor Pressure | Not available |
Vapor Density (air=1) | Not available | Specific Gravity (water=1) | 2.7 |
Water Solubility | 135 % (73 °C) | Partition coefficient: n-octanol/water | Not available |
Viscosity | Not available | Solubility (Other) | Not available |
Change in color | deliquescent | Density | Not available |
Physical Form | crystals | Molecular Formula | H12-N3-O15-Y |
alcohol, ether, nitric acid
Stable at normal temperatures and pressure.
Avoid contact with combustible materials. May ignite or explode on contact with combustible materials. Keep out of water supplies and sewers.
combustible materials
YTTRIUM NITRATE, HEXAHYDRATE: COMBUSTIBLE MATERIALS: May facilitate burning.
oxides of nitrogen
Thermal decomposition products: oxides of nitrogen.
Will not polymerize.
Component Analysis - LD50/LC50
Component Carcinogenicity
None of this product's components are listed by ACGIH, IARC, NTP, DFG or OSHA
YTTRIUM NITRATE, HEXAHYDRATE Inhalation of yttrium compounds may irritate the respiratory tract and cause lung damage.
YTTRIUM NITRATE, HEXAHYDRATE No data available.
YTTRIUM NITRATE, HEXAHYDRATE No data available.
YTTRIUM NITRATE, HEXAHYDRATE No data available.
YTTRIUM NITRATE, HEXAHYDRATE Yttrium compounds may cause irritation and possibly severe damage.
YTTRIUM NITRATE, HEXAHYDRATE No data available.
YTTRIUM NITRATE, HEXAHYDRATE No data available.
YTTRIUM NITRATE, HEXAHYDRATE: No human data available Animal studies indicate that prolonged ingestion of yttrium compounds may cause liver damage.
Component Analysis - Aquatic Toxicity
Dispose in accordance with all applicable regulations.
Component Waste Numbers
Component Marine Pollutants (IMDG)
SARA Section 311/312 (40 CFR 370 Subparts B and C)
Component | CAS | CA | MA | MN | NJ | PA |
YTTRIUM NITRATE, HEXAHYDRATE | 13494-98-9 | Yes | No | Yes | No | No |
Not listed under California Proposition 65
Canadian WHMIS Ingredient Disclosure List (IDL)
YTTRIUM NITRATE, HEXAHYDRATE | 13494-98-9 |
1 % (related to Yttrium compounds) |
Component | CAS# | US | CA | EU | AU | PH | JP | KR | CN | NZ |
YTTRIUM NITRATE, HEXAHYDRATE | 13494-98-9 | No | No | No | Yes | No | Yes | No | Yes | Yes |
The listed component(s) of this material have been checked for country-specific published classifications according to the Globally Harmonized System of Classification and Labeling (GHS). The results of the queries are displayed below. Please see the individual country listings, as additional interpretations or reference information may be available. For a reference list of H- or P-statements, please visit ChemADVISOR’s website at http://www.chemadvisor.com/product-resources/26-pure-substance-and-mixture-databases/247-ghs-hazard-and-physical-statements
Australia GHS Classifications
European Union GHS Classifications
Indonesia GHS Classifications
Japan GHS Classifications
Korea GHS Classifications
New Zealand GHS Classifications
New Zealand GHS Labeling Information
South Africa GHS Classifications
Taiwan GHS Classifications
No classification assigned.
ACGIH - American Conference of Governmental Industrial Hygienists; ADR - European Road Transport; AU - Australia; BOD - Biochemical Oxygen Demand; C - Celsius; CA - Canada; CAS - Chemical Abstracts Service; CERCLA - Comprehensive Environmental Response, Compensation, and Liability Act; CN - China; CPR - Controlled Products Regulations; DFG - Deutsche Forschungsgemeinschaft; DOT - Department of Transportation; DSL - Domestic Substances List; EEC - European Economic Community; EINECS - European Inventory of Existing Commercial Chemical Substances; EPA - Environmental Protection Agency; EU - European Union; F - Fahrenheit; IARC - International Agency for Research on Cancer; IATA - International Air Transport Association; ICAO - International Civil Aviation Organization; IDL - Ingredient Disclosure List; IDLH - Immediately Dangerous to Life and Health; IMDG - International Maritime Dangerous Goods; JP - Japan; Kow - Octanol/water partition coefficient; KR - Korea; LEL - Lower Explosive Limit; LOLI - List Of LIsts™ - ChemADVISOR’s Regulatory Database; MAK - Maximum Concentration Value in the Workplace; MEL - Maximum Exposure Limits; NFPA - National Fire Protection Agency; NIOSH - National Institute for Occupational Safety and Health; NJTSR - New Jersey Trade Secret Registry; NTP - National Toxicology Program; NZ - New Zealand; OSHA - Occupational Safety and Health Administration; PH - Philippines; RCRA - Resource Conservation and Recovery Act; RID - European Rail Transport; RTECS - Registry of Toxic Effects of Chemical Substances®; SARA - Superfund Amendments and Reauthorization Act; STEL - Short-term Exposure Limit; TDG - Transportation of Dangerous Goods; TSCA - Toxic Substances Control Act; TWA - Time Weighted Average; UEL - Upper Explosive Limit; US - United States
Reasonable care has been taken in the preparation of this information; however, the manufacturer makes no warranty whatsoever including the warranty of merchantability, expressed or implied, with respect to this information. The manufacturer makes no representations and assumes no liability for any direct, incidental, consequential, or other such damages resulting from its use or misuse.
Supplier gives no warranty whatsoever, including the warranties of merchantability or of fitness for a particular purpose. Any product purchased is sold on the assumption the purchaser shall determine the quality and suitability of the product. Supplier expressly disclaims any and all liability for incidental, consequential or any other damages arising out of the use or misuse of this product. No information provided shall be deemed to be a recommendation to use any product in conflict with any existing patent rights. THIS SDS IS TO BE UTILIZED SOLELY AS A REFERENCE DOCUMENT AND IT IS NOT TO BE USED TO SATISFY THE DISTRIBUTION REQUIREMENTS OF OSHA'S HAZARD COMMUNICATION STANDARD (HCS) NOR CANADA'S CONTROLLED PRODUCT REGULATION (CPR). Read the Safety Data Sheet before handling product. Use of any information contained herein is provided at the reader's own risk and thus independent judgment by trained professionals must be utilized at all times.
Copyright 1984-2016 ChemADVISOR, Inc "RTECS®" is a United States trademark owned and licensed under authority of the U.S. Government, by and through Accelrys/Biovia. Portions ©Copyright 2016, U.S. Government. All rights reserved